PH120 SR 114E Enhanced Fire Resistant Cable with Rubber , FR-LSZH Jacket
Quick Detail:
- PH120 SR 114E Enhanced Fire Resistant Cable
- 2 Cores / 4 Cores
- 1.0mm2 / 1.5mm2 / 2.5mm2 / 4.0mm2
- Bare Copper Conductor
- Rubber Insulation
- FR-LSZH Jacket
- 200M/500M/Wooden Spool/Carton
- 120 Minutes Under Fire of 840 Degrees without Short-Circuit.
- More details please contact us!
Description:
KT1413 PH120 Fire resistant cable SR 114E Enhanced Rubber Insulation FR-LSZH |
APPLICATION: |
These cables are used for installation in fire systems for connecting fire alarms etc.
The cable can be installed in dry and moist areasas well for fixed open air installation.
This cable type with electrostatic screening (St) protects
the transmission circuits against externelectrical interferences. |
Standards: |
All these cables comply to:
BS 5839-1:2002
Code of practice for fire system design, installation, commissioning and maintenance.
BS 7629-1:2008
Low emission of smoke and corrosive gases
BS EN 50200 PH120
Temperature: 830 °C Flame and shock for 120 minutes. |
|
|
ELECTRICAL DATA (AT20OC) |
Minimum
Bend Radius |
Min.
Insulation
resistance |
Max.Working
Temperature |
Test voltage
(rms value) |
Max.
Operating
voltage
peak value |
|
MΩ/km |
℃ |
V |
V |
8×Diameter |
300 |
-40℃~+90℃ |
1000 |
300/500 |
TYPES AND MECHANICAL DATA |
Types
sqmm
(mm2)
|
Conductor |
Insulation |
Shielded1/
Drain Wire /
Shielded2 |
Level of
twisting |
Jacket
Matterial |
OD of
Jacket (mm) |
2×1.0 |
BC Class 1,2 |
Rubber |
PET/AL-Foil |
TC |
FR-LSZH |
7.00±0.20 |
4×1.0 |
BC Class 1,2 |
Rubber |
PET/AL-Foil |
TC |
FR-LSZH |
8.00±0.20 |
2×1.5 |
BC Class 1,2 |
Rubber |
PET/AL-Foil |
TC |
FR-LSZH |
7.50±0.20 |
4×1.5 |
BC Class 1,2 |
Rubber |
PET/AL-Foil |
TC |
FR-LSZH |
8.60±0.20 |
2×2.5 |
BC Class 1,2 |
Rubber |
PET/AL-Foil |
TC |
FR-LSZH |
8.50±0.20 |
4×2.5 |
BC Class 1,2 |
Rubber |
PET/AL-Foil |
TC |
FR-LSZH |
10.0±0.20 |
2×4.0 |
BC Class 2 |
Rubber |
PET/AL-Foil |
TC |
FR-LSZH |
9.80±0.20 |
4×4.0 |
BC Class 2 |
Rubber |
PET/AL-Foil |
TC |
FR-LSZH |
11.70±0.20 |
|
Class 1,2 |
|
|
|
|
|
*Notes |
Class Types: |
Class1: Solid / Class 2: 7 Cores / Class 5: Flexible |
|
FR-LSZH: |
LSZH thermoplastic material Type LTS3to BS 7656-6.1 |
|
Silicone Rubber: |
High performance silicone rubber EI2 to BS EN 50363-1 |
TECHNICAL DATA |
Types
sqmm
(mm2)
|
Max.Resistance
of Cond.at 20℃ |
Current Carrying
Capacity(Amperes) |
Nominal
Capacitance
(pF/m) |
|
Class 1,2 |
Class 5 |
Clipped |
In Conduit |
Core |
Screen |
1.00 |
18.10 Ω/km |
19.50 Ω/km |
19 |
17 |
100 |
170 |
1.50 |
12.10 Ω/km |
13.30 Ω/km |
24 |
22 |
110 |
190 |
2.50 |
7.41 Ω/km |
7.98 Ω/km |
33 |
30 |
130 |
220 |
4.00 |
4.61 Ω/km |
4.95 Ω/km |
45 |
40 |
160 |
270 |
|
|
|
|
|
|
|
Order Informations: |
Marking |
KINGTONE KT1416 SR 114E Enhanced Cable Cable N*NNmm2 XXX M
|
Package |
500m/Wooden Spool, 1Spool/Carton |
KT1413 PH120 SR 114E Enhanced Fire Resistant Cable with Rubber FR-LSZH Jacket
is a specific type of fire alarm cable Produced by KINGTONE. These cables are used for
installation in fire systems for connecting fire alarms etc. The cable can be installed
in dry and moist areas as well for fixed open air installation. This cable type with
electrostatic screening (St) protects the transmission circuits against extern-electrical
interferences. And all these cables comply to:
IEC60331-23-2003
IEC60332-3-22-2005
IEC61034-2-2005
EC60754-1-99
IEC60754-2-99
IEC60331-21:1999
BS EN 61034-2:2005
BS 7629-1:2008
BS EN 50267-2-1:1999
KINGTONE using best raw material and best worker to produce KT1413 PH120 Fire resistant cable SR 114E Rubber Insulation FR-LSZH to meet high performance in practical application. KT1413 PH120 Fire resistant cable SR 114E Rubber Insulation FR-LSZH is packed in 200m Reel, 2~10 Reels /Carton, then will be layed on pallet to protect the spool and easier carry.Because of good managing methods,
KINGTONE’S price of KT1413 PH120 Fire resistant cable SR 114E Rubber Insulation FR-LSZH is not high although our quality is really high.
Applications:
These cables are used for installation in fire systems for connecting fire alarms etc.
The cable can be installed in dry and moist areas as well for fixed open air installation.
This cable type with electrostatic screening (St) protects the transmission circuits
against extern-electrical interferences.