CAT 6A Network Cable |
|
|
Application: |
Telephony Voice Wiring,10 Base-T,100 Base-T4 |
UL Subject 444,EIA/TIA568 & ISO/IEC 11801 |
|
|
|
|
|
|
|
Construction |
Center conductor |
4x2x0.573mm Bare Copper |
Dielectric |
1.05mm PE |
Drain Wire |
0.5mm Tinned Copper |
Shield |
AL/PE Foil |
Rip |
Cotton |
Outer jacket |
7.4mm PVC |
|
|
|
|
|
|
|
Electrical Characteristics at 20 °C |
Conductor resistance (Max.) |
9.38 Ω/100m |
Insulation resistance (Min.) |
5000 MΩ.km |
Capacitance |
< 330 pF/100m |
Impedance |
100 Ω (± 5%) |
Transport and storage temperature |
0 +50 °C |
Operating temperature |
-20 +60 °C |
|
|
|
|
|
|
|
Performance Characteristics |
Frequency |
Attenuation (Max.) |
Near End (dB) |
ACRF (dB/100m) |
PS-NEXT |
PS-ACRF |
Return Loss |
1 MHz |
2.1 dB/100m |
74.3 |
67.8 |
72.3 |
64.8 |
20 dB |
10 MHz |
5.9 dB/100m |
59.3 |
47.8 |
57.3 |
44.8 |
25 dB |
16 MHz |
7.5 dB/100m |
43.7 |
56.2 |
54.2 |
40.7 |
25 dB |
20 MHz |
8.4 dB/100m |
54.8 |
54.8 |
52.8 |
38.8 |
25 dB |
25 MHz |
9.4 dB/100m |
53.3 |
39.8 |
51.3 |
36.8 |
24.3 dB |
62.5 MHz |
15.0 dB/100m |
47.4 |
31.9 |
45.4 |
28.9 |
21.5 dB |
100 MHz |
19.1 dB/100m |
44.3 |
27.8 |
42.3 |
18.8 |
20.1 dB |
200 MHz |
27.6 dB/100m |
27.6 |
21.8 |
37.8 |
18.8 |
18.0 dB |
300MHz |
34.3 dB/100m |
34.3 |
18.3 |
35.1 |
15.3 |
16.8 dB |
500MHz |
45.3 dB/100m |
45.3 |
13.8 |
31.8 |
10.8 |
15.2 dB |
* PVC – Polyvinylchlorid * AWG - American Wire Gauge * AL/PE - Aluminium/Polyethylene |